Electron counting and beam-induced motion correction enable near atomic resolution single particle cryoEM
By Xueming Li, P. Mooney, S. Zheng, C. Booth, M. Braunfeld, S. Gubbens, David A. Agard, Yifan Cheng. 2013
1,835 citations recorded by the source corpus.
In recent work with large high-symmetry viruses, single-particle electron cryomicroscopy (cryo-EM) has achieved the determination of near-atomic-resolution structures by allowing direct fitting of atomic models into experimental density maps. However, achieving this goal with smaller particles of lower symmetry remains challenging. Using a newly developed single electron–counting detector, we confirmed that electron beam–induced motion substantially degrades resolution, and we showed that the combination of rapid readout and nearly noiseless electron counting allow image blurring to be corrected to subpixel accuracy, restoring intrinsic image information to high resolution (Thon rings visible to ∼3 Å). Using this approach, we determined a 3.3-Å-resolution structure of an ∼700-kDa protein with D7 symmetry, the Thermoplasma acidophilum 20S proteasome, showing clear side-chain density. Our method greatly enhances image quality and data acquisition efficiency—key bottlenecks in applying near-atomic-resolution cryo-EM to a broad range of protein samples.
Subfields: Materials Chemistry, Molecular Biology, Structural Biology
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Materials Chemistry
- Paul D. Adams
- Pavel V. Afonine
- Randy J. Read
- T. Croll
- T. C. Terwilliger
- Nigel W. Moriarty
- A. McCoy
- Jane S. Richardson
In Molecular Biology
- Paul D. Adams
- Randy J. Read
- Pavel V. Afonine
- T. C. Terwilliger
- T. Croll
- Nigel W. Moriarty
- G. Bunkoczi
- David Baker
In Structural Biology
- Sjors H. W. Scheres
- Dari Kimanius
- Kai Zhang
- Erik Lindahl
- T. Croll
- Yifan Cheng
- Takanori Nakane
- Björn Forsberg
Citations in the corpus
- Macromolecular structure determination using X-rays, neutrons and electrons: recent developments in Phenix (2019, methodology): “Technological advances, such as the development of direct electron detectors (Li et al., 2013) and improvements in image processing (Bai et al., 2015), have transformed the method, leading to cryo-EM maps with greatly improved resolution.”
- New tools for automated high-resolution cryo-EM structure determination in RELION-3 (2018, background): “Some new programs exploited specific opportunities provided by the new detectors, like the correction of beam-induced motions through movie processing ( Brilot et al., 2012 ; Li et al., 2013 ; Rubinstein and Brubaker, 2015 ; Abrishami et al., 2015 ; McLeod et al., 2017 ; Zheng et al., 2017 ).”
- Gctf: Real-time CTF determination and correction (2015, background): “Beam induced movement correction using movies has greatly improved the resolution of the final reconstruction(Bai et al., 2013; Li et al., 2013).”
- Processing of Structurally Heterogeneous Cryo-EM Data in RELION. (2016, methodology): “This step is often performed using the MOTIONCORR program (Li et al., 2013).”
- Single-Particle Cryo-EM at Crystallographic Resolution. (2015, methodology): “better balance between the requirements for both image contrast and high-resolution signal (Li et al., 2013; Liao et al., 2013; Lu et al., 2014).”
- Reconstructing continuous distributions of 3D protein structure from cryo-EM images (2019, background): “Despite these challenges, continuing advances in hardware and software have enabled structure determination at near-atomic resolution for rigid proteins (Kühlbrandt (2014); Scheres (2012b); Renaud et al. (2018); Li et al. (2013)).”
- Measuring the optimal exposure for single particle cryo-EM using a 2.6 Å reconstruction of rotavirus VP6 (2015, background): “The ability to record movies instead of single images allows for easy collection of a continuous exposure series, while allowing for measurement and correction of specimen movement (Brilot et al., 2012; Campbell et al., 2012; Li et al., 2013; Scheres, 2014).”
- Unified Polymerization Mechanism for the Assembly of ASC-dependent Inflammasomes (2014, background): “…a state-of-the-art electron microscope (the Titan Krios), and a new generation of direct electron detectors (Bai et al., 2013; Bammes et al., 2012; Li et al., 2013; Liao et al., 2013), combined with existing computational approaches for variable twist polymers (Egelman, 2000; Egelman et al.,…”
- Structure and Dynamics of a 197 bp Nucleosome in Complex with Linker Histone H1. (2017, background): “…DNA 343 bp Widom 601 DNA Liu et al., 2011 N/A 207 bp Widom 601 DNA Wang and Hayes, 2008 N/A Software and Algorithms MotionCorr Li et al., 2013 http://cryoem.ucsf.edu/software/driftcorr.html Xmipp Optical Flow Abrishami et al., 2015…”