Three-dimensional head model Simulation of transcranial magnetic stimulation
By Tim A. Wagner, Markus Zahn, Alan J. Grodzinsky, Alvaro Pascual-Leone. IEEE Transactions on Biomedical Engineering, 2004
332 citations recorded by the source corpus.
Subfields: Biomedical Engineering, Cellular and Molecular Neuroscience, Neurology
View Paper: https://www.semanticscholar.org/paper/e281a45c9d18e89054b2b6f67b72cee8e22ad455
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Biomedical Engineering
In Cellular and Molecular Neuroscience
- Alvaro Pascual-Leone
- Axel Thielscher
- Mark Hallett
- Paolo Maria Rossini
- Mirko Windhoff
- Alexander Opitz
- Pedro Cavaleiro Miranda
- Giulio Ruffini
In Neurology
- Axel Thielscher
- Alvaro Pascual-Leone
- Mirko Windhoff
- Alexander Opitz
- Felipe Fregni
- Mark Hallett
- Paolo Maria Rossini
- Simone Rossi
Citations in the corpus
- Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research (2009, background): “However, such clinical interpretations need to be reevaluated in light of recent modeling work (Nadeem et al., 2003; Miranda et al., 2003; Wagner et al., 2004; De Lucia et al., 2007) that clearly demonstrate the importance of accounting for the actual head model geometry, tissue…”
- Impact of the gyral geometry on the electric field induced by transcranial magnetic stimulation (2011, unknown): “values were taken from (Wagner et al., 2004) and represent mean values frommultiple”
- How the brain tissue shapes the electric field induced by transcranial magnetic stimulation (2011, methodology): “126 S/m were used as isotropic reference values that represent mean values from multiple references (Wagner et al., 2004).”
- The electric field in the cortex during transcranial current stimulation (2013, background): “However, the approximation fails for very high permittivity values (Wagner et al., 2004), inwhich case anAC calculation taking into account tissue permittivitiesmust be carried out to obtain an accurate estimate of the electric field in the brain.”
- Transcranial direct current stimulation: A computer-based human model study (2007, methodology): “The MRI images were used to segment the modeled tissues in the FEM space, guiding the mesh generation based on the MRI-derived tissue boundaries, the process of which is detailed in Wagner et al. (2004).”