Membrane imaging by second-harmonic generation microscopy
By L. Moreaux, Olivier Sandre, J. Mertz. 2000
331 citations recorded by the source corpus.
Subfields: Atomic and Molecular Physics, and Optics, Biomedical Engineering, Biophysics
View Paper: https://www.semanticscholar.org/paper/d9f9a064823ca46f04d59349dbd19968d1bec6a0
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Atomic and Molecular Physics, and Optics
In Biomedical Engineering
In Biophysics
- Rakesh K. Jain
- Rebecca M. Williams
- W. Zipfel
- W. Webb
- P. Campagnola
- Justin Lee
- Shuai Li
- George Barbastathis
Citations in the corpus
- Nonlinear magic: multiphoton microscopy in the biosciences (2003, background): “SHG directionality is dependent on the distribution and directionality of the induced dipoles within the focal volum”
- Theoretical and experimental characterization of coherent anti-Stokes Raman scattering microscopy (2002, unknown): “PNR ~3 ~r! 5 3x1111 ~3 ~vas!Ep (2)~r!Es * ~r!cos f/cos f, (19)”
- Interpreting second-harmonic generation images of collagen I fibrils. (2005, background): “Fits to exact field calculations (Richards andWolf, 1959) yield explicit values for the size of the focal volume (Zipfel et al., 2003b): w ¼ 0:32lv nvsinQ and wz ¼ 0:53lv nvð1 cosQÞ ; (6) where nvsinQ is the N.A. of the microscope objective.”
- Dynamic imaging of collagen and its modulation in tumors in vivo using second-harmonic generation (2003, background): “SHG imaging offers many advantages: SHG is an intrinsic signal and does not require the addition of extrinsic dyes; the signal and background are better than those of autofluorescence imaging; nonlinear excitation permits three-dimensional resolution in vivo”
- Imaging through glass diffusers using densely connected convolutional networks (2017, background): “lized in any particular situation. A number of ingenious strategies have been devised to design forward operators that improve the imaging problem’s condition, most famously by using nonlinear optics [3, 4] or stimulated emission [5]. Restricting oneself to linear optics, structured illumination [6–”
- Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms (2003, background): “The last technology is required, especially for imaging dye-stained cells, because the SHG signal power per incident photon is much smaller than that for TPE”