Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
By T. Reese, O. Heid, R. Weisskoff, Van J. Wedeen. Magnetic Resonance in Medicine, 2003
1,303 citations recorded by the source corpus.
Subfields: Nuclear and High Energy Physics, Radiology, Nuclear Medicine and Imaging
View Paper: https://www.semanticscholar.org/paper/a0a54734c749107c97a31da27a88954c052d01de
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Nuclear and High Energy Physics
- Els Fieremans
- Denis Le Bihan
- Jacques-Donald Tournier
- Jesper L. R. Andersson
- Alan Connelly
- Fernando Calamante
- Hui Zhang
- Jens H. Jensen
In Radiology, Nuclear Medicine and Imaging
- Jacques-Donald Tournier
- Stephen M. Smith
- Alan Connelly
- Saâd Jbabdi
- Heidi Johansen-Berg
- Fernando Calamante
- Matthew F. Glasser
- Olaf Sporns
Citations in the corpus
- Evidence for Segregated and Integrative Connectivity Patterns in the Human Basal Ganglia (2008, methodology): “Diffusion weighted imaging (DWI) was performed with an echo planar sequence comprising a double spin-echo module to reduce the effect of eddy currents (Reese et al., 2003).”
- NTU-90: A high angular resolution brain atlas constructed by q-space diffeomorphic reconstruction (2011, methodology): “The diffusion images were acquired by using a pulsegradient spin-echo diffusion EPI sequence with twice-refocused balanced echo (Reese et al., 2003).”
- Towards a comprehensive framework for movement and distortion correction of diffusion MR images: Within volume movement (2017, methodology): “This may be su ffi cient for fetal imaging where there are no air-fi lled sinuses or ear canals that disrupt the fi eld, and if an eddy current-nulled sequence is used to minimise eddy currents (Reese et al., 2003).”
- Pushing the limits of in vivo diffusion MRI for the Human Connectome Project (2013, background): “(Reese et al., 2003) Unfortunately, concomitant terms make this approach impossible (see next paragraph).”
- Characterization and propagation of uncertainty in diffusion‐weighted MR imaging (2003, background): “T ri [ 17 ] where V is the set of all voxels whose principal fiber direction is (, ) and N is the number of subvoxels.”
- Robust determination of the fibre orientation distribution in diffusion MRI: Non-negativity constrained super-resolved spherical deconvolution (2007, methodology): “Data set D was acquired from a healthy volunteer on a 1.5T Siemens Avanto system, using an eddy-current-nulled twicerefocused EPI sequence (Reese et al., 2003) (b-value=1000 s/mm2, TE=89 ms, 20 DW directions, in-plane resolution 2.5×2.5 mm2, 2.5 mm slice thickness, 45 contiguous axial slices, 2…”
- Compartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison (2012, neutral): “, 2010), twice-refocused spin echo sequences (Clayden et al., 2009; Reese et al., 2003), or double wave vector sequences (Koch and Finsterbusch, 2008; Mitra, 1995; Shemesh et al.”
- Pushing spatial and temporal resolution for functional and diffusion MRI in the Human Connectome Project (2013, methodology): “In a spin echo implementation, if two refocusing RF pulses are used, for example to mitigate the eddy current effects due to diffusion encoding gradients (Feinberg and Jakab, 1990; Reese et al., 2003), time-shifted multi-banded refocusing RF pulses can simply be used in place of single-banded pulses”
- Diffusion tensor imaging of the brain (2007, positive): “To a certain degree, the eddy currents may be reduced using bipolar diffusion-weighting schemes.(16,17)”
- Automated quality control for within and between studies diffusion MRI data using a non-parametric framework for movement and distortion correction (2018, methodology): “The eddy current-parameters (left panel) re fl ect both hardware and sequence factors, such as for example Stejskal-Tanner versus twice-refocused diffusion encoding (Reese et al., 2003), that should be accounted for when designing a dMRI experiment.”
- Blipped-Controlled Aliasing in Parallel Imaging (blipped-CAIPI) for simultaneous multi-slice EPI with reduced g-factor penalty (2011, methodology): “The SE-EPI diffusion-weighted imaging was performed with a twice-refocused sequence (21,22) using either conventional single-slice imaging or a 3 slice-accelerated simultaneous multislice acquisition.”
- Twenty‐five pitfalls in the analysis of diffusion MRI data (2010, background): “[9] trivially becomes: P 1⁄4 B (1)L PITFALL 7: HETEROSCEDASTICITY IN THE FITTED DATA WHEN USING LINEAR REGRESSION The first pitfall of analysis is the assumption that the noise in the fitted data is i.”
- Imaging brain microstructure with diffusion MRI: practicality and applications (2019, background): “For example, the level of eddy currents can be reduced by implementing SDE in a double spin-echo sequence or with asymmetric gradients [71, 72].”
- Improving diffusion MRI using simultaneous multi-slice echo planar imaging (2012, methodology): “=3 twice-refocused spin echo sequence (Feinberg and Jakab, 1990; Reese et al., 2003) that together provided good slice selection profiles while staying under the SAR limit.”