Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi‐slice imaging
By Felix Breuer, M. Blaimer, R. Heidemann, Matthias F. Mueller, Mark A. Griswold, P. Jakob. Magnetic Resonance in Medicine, 2005
663 citations recorded by the source corpus.
Subfields: Radiology, Nuclear Medicine and Imaging
View Paper: https://www.semanticscholar.org/paper/76eae1d4eb379e16006ebf9915b6e922e7447c1d
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Radiology, Nuclear Medicine and Imaging
- Stephen M. Smith
- Olaf Sporns
- Matthew F. Glasser
- Kamil Ugurbil
- Jesper L. R. Andersson
- David A. Feinberg
- Essa Yacoub
- Saâd Jbabdi
Citations in the corpus
- Resting-state fMRI in the Human Connectome Project (2013, methodology): “Controlled aliasing (CAIPIRINHA — Breuer et al., 2005) principles can be applied to slice accelerated multiband EPI, following the slicegradient “blipping” strategy of Nunes et al. (2006), while minimizing the detrimental accrual of phase dispersion along the slice thickness leading to a voxel tilt.”
- Pushing the limits of in vivo diffusion MRI for the Human Connectome Project (2013, methodology): “(Breuer et al., 2005) This in-plane shift was achieved by modulating the phase of the magnetization excited in the individual slices for each k-space line by phase modulating each RF pulse.”
- Parallel MR imaging (2012, methodology): “As illustrated in Figure 13, CAIPIRINHA can be used in 3D scans to reduce the number of pixels that alias on top of each other, thereby reducing the g-factor-related noise enhancement in the parallel imaging reconstruction (17,18).”
- Simultaneous multislice (SMS) imaging techniques (2015, methodology): “In the original publication (13), these shifts were accomplished by RF-phase encoding, analogous to POMP.”
- Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA) (2006, background): “Recently, we have shown that these requirements in simultaneous multi-slice imaging can be partially overcome by shifting the individual slices with respect to each other in a controlled manner (MS CAIPIRINHA (10)).”
- Pushing spatial and temporal resolution for functional and diffusion MRI in the Human Connectome Project (2013, methodology): “With the development of control aliasing principles (Breuer et al., 2005) in Multiband EPI (Setsompop et al., 2012), it became possible to attain high slice acceleration factors with Multiband EPI alone without multiplexing with SIR.”
- Improving diffusion MRI using simultaneous multi-slice echo planar imaging (2012, methodology): “The controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique (Breuer et al., 2005) was developed to reduce the g-factor penalty of parallel imaging based simultaneous multi-slice acquisition.”
- Ultra-Fast MRI of the Human Brain with Simultaneous Multi-Slice Imaging (2013, methodology): “The ‘‘controlled aliasing in parallel imaging results in higher acceleration’’ (CAIPIRINHA) technique was proposed by the Wurzburg group [39] to mitigate this issue by introducing”
- Evaluation of slice accelerations using multiband echo planar imaging at 3 Tesla (2013, positive): “The ability to unalias the MB GRE slices was improved by the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) method (Breuer et al., 2005).”
- Blipped-Controlled Aliasing in Parallel Imaging (blipped-CAIPI) for simultaneous multi-slice EPI with reduced g-factor penalty (2011, background): “The SENSE algorithm (3) can be directly adapted for simultaneous multislice imaging acquisition (14,15).”