Semi-automated selection of cryo-EM particles in RELION-1.3
By Sjors H. W. Scheres. 2015
375 citations recorded by the source corpus.
The selection of particles suitable for high-resolution cryo-EM structure determination from noisy micrographs may represent a tedious and time-consuming step. Here, a semi-automated particle selection procedure is presented that has been implemented within the open-source software RELION. At the heart of the procedure lies a fully CTF-corrected template-based picking algorithm, which is supplemented by a fast sorting algorithm and reference-free 2D class averaging to remove false positives. With only limited user-interaction, the proposed procedure yields results that are comparable to manual particle selection. Together with an improved graphical user interface, these developments further contribute to turning RELION from a stand-alone refinement program into a convenient image processing pipeline for the entire single-particle approach.
Subfields: Materials Chemistry, Structural Biology, Surfaces, Coatings and Films
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Materials Chemistry
- Shaoda He
- Sjors H. W. Scheres
- Dari Kimanius
- Erik Lindahl
- Björn Forsberg
- Ouyang Qi
- Youdong Mao
- Yanan Zhu
In Structural Biology
- Shaoda He
- Dari Kimanius
- Takanori Nakane
- Erik Lindahl
- Björn Forsberg
- W. Hagen
- Jasenko Zivanov
- Youdong Mao
In Surfaces, Coatings and Films
- Shaoda He
- Dari Kimanius
- Erik Lindahl
- Takanori Nakane
- Youdong Mao
- Ouyang Qi
- Björn Forsberg
- Jasenko Zivanov
Citations in the corpus
- New tools for automated high-resolution cryo-EM structure determination in RELION-3 (2018, methodology): “The recommended procedure for the selection of particles from micrographs in previous versions of RELION was to calculate templates for reference-based auto-picking from particles that were manually picked in a subset of the micrographs ( Scheres, 2015 ).”
- Processing of Structurally Heterogeneous Cryo-EM Data in RELION. (2016, methodology): “The resulting regularized likelihood optimization algorithm has proven useful for both highresolution reconstruction as well as 2D or 3D classification in a wide range of experimental studies (Bai, McMullan, & Scheres, 2015).”
- A deep convolutional neural network approach to single-particle recognition in cryo-electron microscopy (2016, methodology): “A comparison of the precision-recall curves between DeepEM, RELION [36] and TMACS [16] suggests that DeepEM outperforms these two template-matching based methods (Additional file 1: Figure S4).”
- Automated Particle Picking in Cryo-Electron Micrographs using Deep Regression (2018, methodology): “We selected 10 micrographs from the EMPIAR-10017 dataset (β-galactosidase) to train our FCRN model and FasterRCNN.”
- Decoding Mammalian Ribosome-mRNA States by Translational GTPase Complexes (2016, methodology): “Reference-free two-dimensional class averagingwas used to discard non-ribosomal particles, with those picked using RELION subjected to an additional sorting step (Scheres, 2015).”
- Cryo-EM structure of the adenosine A2A receptor coupled to an engineered heterotrimeric G protein (2018, neutral): “Construction of the 399 thioredoxin-A2AR fusion protein and C-terminally truncated A2AR (1-317), both containing 400 the N154A mutation, is described elsewhere(29).”