Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo
By W. Rooney, G. Johnson, Xin Li, E. R. Cohen, Seong-Gi Kim, Kamil Ugurbil, C. Springer. Magnetic Resonance in Medicine, 2007
666 citations recorded by the source corpus.
Subfields: Biophysics, Radiology, Nuclear Medicine and Imaging, Spectroscopy
View Paper: https://www.semanticscholar.org/paper/1dbeb7400deb09d86c59dc4f7b09b068c05d93db
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Biophysics
In Radiology, Nuclear Medicine and Imaging
- Stephen M. Smith
- Matthew F. Glasser
- Olaf Sporns
- Kamil Ugurbil
- Jesper L. R. Andersson
- Essa Yacoub
- Stamatios N. Sotiropoulos
- Saâd Jbabdi
In Spectroscopy
Citations in the corpus
- MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field (2010, result): “…(2008) 3 T 0.84±0.05 1.33±0.07 1.39±0.05 1.61±0.10 MPRAGE, 8 TIs, 20 slices, 15 mm This study 3 T 0.81±0.03 1.13±0.07 1.25±0.07 1.35±0.05 MP2RAGE, 160 slice, 1 mm Rooney et al. (2007) 7 T 1.22±0.03 1.70±0.07 1.75±0.06 2.13±0.10 Look locker sequence, 32 inversion times, single slice, 5 mm Wright et…”
- Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validation (2013, background): “Thus, a direct comparison and pooling of data across field strengths are complicated but may not be impossible using appropriate relaxometry models (Rooney et al., 2007).”
- Blipped-Controlled Aliasing in Parallel Imaging (blipped-CAIPI) for simultaneous multi-slice EPI with reduced g-factor penalty (2011, background): “White matter (T1 of 850 ms at 3 T (28)) is the main focus of diffusion imaging.”
- Using high-resolution quantitative mapping of R1 as an index of cortical myelination (2014, neutral): “Because MR parameters are a mixed effect of multiple tissue properties (Gelman et al., 2001; Rooney et al., 2007), a complete insight into tissue micro-architecture requires quantification of multiple MR parameters.”
- Myelin and iron concentration in the human brain: A quantitative study of MRI contrast (2014, methodology): “Modern QSM quantitative techniques allow testing of the validity 118 of theoretical physical models which have attempted to derive regres- 119 sion coefficients for the relative contributions of iron and myelin in T 1 120 maps (Rooney et al., 2007), T 2 * maps and QSM (Schweser et al., 2011).”
- Nuclear Overhauser Enhancement (NOE) Imaging in the Human Brain at 7 T (2013, neutral): “Recycle times of 8 s and 6 s (>3 T1 at 7 T (Rooney et al., 2007)) were used in vitro and in vivo, respectively, which should allow for sufficient regrowth of the longitudinal magnetization between acquisitions.”
- Pushing spatial and temporal resolution for functional and diffusion MRI in the Human Connectome Project (2013, background): “The longer T1 (Rooney et al., 2007) is also a disadvantage for SNR per unit time.”