Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions
By Pedro Rodriguez, Alvaro Luna, I. Candela, Ramon Mujal, Remus Teodorescu, Frede Blaabjerg. IEEE transactions on industrial electronics (1982. Print), 2011
1,105 citations recorded by the source corpus.
This paper presents a new multiresonant frequency-adaptive synchronization method for grid-connected power converters that allows estimating not only the positive- and negative-sequence components of the power signal at the fundamental frequency but also other sequence components at other harmonic frequencies. The proposed system is called MSOGI-FLL since it is based on both a harmonic decoupling network consisting of multiple second-order generalized integrators (MSOGIs) and a frequency-locked loop (FLL), which makes the system frequency adaptive. In this paper, the MSOGI-FLL is analyzed for single- and three-phase applications, deducing some key expressions regarding its stability and tuning. Moreover, the performance of the MSOGI-FLL is evaluated by both simulations and experiments to show its capability for detecting different harmonic components in a highly polluted grid scenario.
Subfields: Control and Systems Engineering, Electrical and Electronic Engineering, Energy Engineering and Power Technology
View Paper: https://www.semanticscholar.org/paper/f389d34d5eb85a12e715c4adcf8cd95408065580
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Control and Systems Engineering
- Frede Blaabjerg
- Josep M. Guerrero
- Poh Chiang Loh
- Juan Carlos Vasquez
- Xiongfei Wang
- Avinash Kumar Sinha
- Navneet Kishore
- S. K. Sahoo
In Electrical and Electronic Engineering
- Frede Blaabjerg
- Poh Chiang Loh
- Josep M. Guerrero
- Juan Carlos Vasquez
- Xiongfei Wang
- Avinash Kumar Sinha
- Navneet Kishore
- S. K. Sahoo
In Energy Engineering and Power Technology
- Xiongfei Wang
- Poh Chiang Loh
- Zhen Xin
- Saeed Golestan
- Josep M. Guerrero
- Avinash Kumar Sinha
- Navneet Kishore
- S. K. Sahoo
Citations in the corpus
- A Novel Flux Estimator Based on Multiple Second-Order Generalized Integrators and Frequency-Locked Loop for Induction Motor Drives (2017, methodology): “SOGI has been widely used for extracting a sinusoid in-phase and another in-quadrature with the grid voltage [11]–[14].”
- A review on fundamental grid-voltage detection methods under highly distorted conditions in distributed power-generation networks (2011, methodology): “A detailed study about the tuning and the improvement of the voltage rejection abilities of the DSOGI-PLL is presented in [18].”
- An Improved Flux Observer for Field-Oriented Control of Induction Motors Based on Dual Second-Order Generalized Integrator Frequency-Locked Loop (2017, methodology): “The differential equations (19)–(22) [26]–[28] can be obtained from the diagram of SOGI-FLL shown in Fig.”
- Control Techniques in AC, DC, and Hybrid AC–DC Microgrid: A Review (2018, methodology): “However, this PLL technique fails under grid unbalance and distortion conditions, in the presence of unbalanced and nonlinear loads [23].”
- An Adaptive Synchronous-Reference-Frame Phase-Locked Loop for Power Quality Improvement in a Polluted Utility Grid (2012, methodology): “In [31], a method to detect the fundamental frequency of the utility grid regardless of the presence of imbalance or harmonic distortion is shown.”
- A Family of Gradient Descent Grid Frequency Estimators for the SOGI Filter (2018, methodology): “In [28] and [29], it was used with a “multiple SOGI” (MSOGI-FLL) structure for the fast detection”
- Three-Phase PLLs: A Review of Recent Advances (2017, positive): “To improve the harmonic ltering capability of the DSOGI-PLL additional QSG-SOGIs tuned at harmonic frequencies can be added to the standard structure [117].”
- Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters (2018, neutral): “Ls, such as decoupled double synchronous reference frame PLL (DDSRF-PLL) [20], delayed signal cancellation based PLL (DSC-PLL) [21]-[22], second-order generalized integrator based PLL (SOGI-PLL) [23]-[24], etc. II. GRID-CONNECTED VOLTAGE SOURCE CONVERTERS A. System Description Fig. 2 illustrates the”
- Design-Oriented Study of Advanced Synchronous Reference Frame Phase-Locked Loops (2013, methodology): “The zero-crossing detection methods [1], [2], the space-vector filtering method [3], the artificialneural-network-based method [4], the recursive weighted leastsquares estimation algorithm [5], the discrete Fourier transform and its modifications [6], [7], the methods based on the concept of adaptiv”
- Finite Control Set Model Predictive Current Control for Grid-Connected Voltage-Source Converters With LCL Filters: A Study Based on Different State Feedbacks (2016, methodology): “The initial system values are extracted from uPCC with phase-locked loops based on multiple second-order generalized integrators (MSOGI-PLL) [36] d dt x(t) = A [s (t)] x(t) (14) x = [if c if g uf udc iload uPCC1+ uPCC1− uPCC5− uPCC7+ ] T (15) A [s(t)] = ⎡ ⎢⎢⎢⎢⎢⎢⎢⎢⎢⎣ A2 [s (t)] B2 B2 B2 B2 0 jω 0 0 0”
- An Improved Second-Order Generalized Integrator Based Quadrature Signal Generator (2016, methodology): “Besides that the possible presence of input harmonics with unknown frequencies may post a second challenge, which strictly, cannot be solved by MSOGI-QSG from [5] since it requires prior knowledge of the harmonic frequencies.”