Three-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction Microscopy
By Bo Huang, Wenqin Wang, M. Bates, X. Zhuang. Science, 2008
2,752 citations recorded by the source corpus.
Subfields: Atomic and Molecular Physics, and Optics, Biomedical Engineering, Biophysics
View Paper: https://www.semanticscholar.org/paper/ccc40ade680b929c47eae55127ccba4fcea42a55
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Atomic and Molecular Physics, and Optics
- Stefan W. Hell
- Christian Cierpka
- Christian J. Kähler
- X. Zhuang
- M. Bates
- Marta Fernandez-Suarez
- A. Ting
- Bo Huang
In Biomedical Engineering
- X. Zhuang
- Stefan W. Hell
- Bo Huang
- M. Bates
- A. Ting
- Marta Fernandez-Suarez
- Christian Cierpka
- Christian J. Kähler
In Biophysics
- X. Zhuang
- Stefan W. Hell
- Bo Huang
- M. Bates
- A. Ting
- Marta Fernandez-Suarez
- D. Baddeley
- Mark B. Cannell
Citations in the corpus
- Defining mechanisms that regulate RNA polymerase II transcription in vivo (2009, neutral): “and stochastic optical reconstruction microscopy/photo-activated localization microscop”
- Nuclear pores as versatile reference standards for quantitative superresolution microscopy (2019, neutral): “2i, based on a RIMF of 0.8), and thus smaller than the true value of 49.3 nm.”
- Super-resolution chromatin tracing reveals domains and cooperative interactions in single cells (2018, methodology): “M. J. Rust, M. Bates, X. Zhuang, Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM).”
- Three-dimensional sub-100 nm super-resolution imaging of biological samples using a phase ramp in the objective pupil (2011, methodology): “A reconstruction at conventional, diffraction-limited resolution is shown for comparison To compare our PRILM method with astigmatic detection [ 7 ], we conducted similar experiments using an astigmatic PSF and imaged the same sample of β-tubulin-stained cardiac myocytes.”
- ThunderSTORM: a comprehensive ImageJ plug-in for PALM and STORM data analysis and super-resolution imaging (2014, methodology): “, 2011; Izeddin et al., 2012), by detection of local maxima, non-maximum suppression or calculation of the centroid of connected components of segmented objects. A feature exclusively unique to ThunderSTORM is the possibility of specifying the threshold for detection of molecules using a mathematica”
- Microscopy and its focal switch (2008, background): “, but, if background is low, three-dimensional recording is possible and has been demonstrate”