Brain responses to micro-machined silicon devices.
By D. Szarowski, M. Andersen, S. Retterer, A. Spence, M. Isaacson, Harold G. Craighead, J. N. Turner, William Shain. Brain Research, 2003
787 citations recorded by the source corpus.
Subfields: Biomedical Engineering, Cellular and Molecular Neuroscience, Cognitive Neuroscience
View Paper: https://www.semanticscholar.org/paper/a9b1f059a75d6e6fc277c0a507fd00aef691c2ff
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Biomedical Engineering
- Christoph Weder
- Jeffrey R. Capadona
- K. Shanmuganathan
- Krishna V. Shenoy
- John P. Cunningham
- John P. Donoghue
- Mark M. Churchland
In Cellular and Molecular Neuroscience
- John P. Donoghue
- Krishna V. Shenoy
- Mehdi Jorfi
- John P. Cunningham
- Jeffrey R. Capadona
- Christoph Weder
- John Skousen
- Daryl R. Kipke
In Cognitive Neuroscience
- John P. Cunningham
- Krishna V. Shenoy
- John P. Donoghue
- Mark M. Churchland
- Mehdi Jorfi
- Stephen I. Ryu
- Jeffrey R. Capadona
- Christoph Weder
Citations in the corpus
- Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex (2011, background): “For monkey J, these data may also be consistent with tissue response studies in which there is a period of rapid decline in the amplitudes of single units during the first 12 weeks [22, 24, 28].”
- Response of brain tissue to chronically implanted neural electrodes. (2005, methodology): “This reaction is characterized by the presence of both reactive astrocytes, which form a glial scar (detailed in the next section), and activated microglia (Stensaas and Stensaas, 1976; Turner et al., 1999; Szarowski et al., 2003; Biran et al., 2005).”
- Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex (2004, methodology): “The impedance data are consistent with the idea that the short-term and most pronounced immune response plateaus after about three weeks [ 31 ] and then reaches some form of steady state.”
- Progress Towards Biocompatible Intracortical Microelectrodes for Neural Interfacing Applications (2014, background): “Szarwoski et al conducted the first study investigating the potential of changing device architecture to alter the neuro-inflammatory response [239].”
- Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film (2006, neutral): “to implanted silicon probes reported elsewhere [31, 45, 52].”
- Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex (2005, methodology): “Investigators in other studies have documented vascular damage using Perl’s Prussian Blue reaction and local inflammatory responses with glial fibrillary acidic protein (GFAP) staining, after array insertion and following a period of stabilization over several weeks [14], [ 15 ].”
- Development of a stimuli-responsive polymer nanocomposite toward biologically optimized, MEMS-based neural probes (2011, background): “limiting electrode viability to only several months [18].”