Overview of Control and Grid Synchronization for Distributed Power Generation Systems
By Frede Blaabjerg, Remus Teodorescu, Marco Liserre, Adrian V. Timbus. IEEE transactions on industrial electronics (1982. Print), 2006
5,304 citations recorded by the source corpus.
Subfields: Control and Systems Engineering, Electrical and Electronic Engineering
View Paper: https://www.semanticscholar.org/paper/7278b8287c5ccd3334c4fa67e82d368c94a5af21
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Control and Systems Engineering
- Frede Blaabjerg
- Xiongfei Wang
- Yun Wei Li
- Poh Chiang Loh
- Friedrich Wilhelm Fuchs
- Yunjie Gu
- T. Green
- Josep M. Guerrero
In Electrical and Electronic Engineering
- Frede Blaabjerg
- Xiongfei Wang
- José Raúl Rodríguez Rodríguez
- Yun Wei Li
- Poh Chiang Loh
- Josep M. Guerrero
- Marco Liserre
- Yunjie Gu
Citations in the corpus
- Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters (2014, background): “Most grid-connected VSCs use current control in a rotating (dq) reference frame [8], which is synchronized to the fundamental component of the grid voltages by means of a phase-locked loop (PLL) [9].”
- Weighting Factor Design in Model Predictive Control of Power Electronic Converters: An Artificial Neural Network Approach (2019, neutral): “classical linear control approaches [3].”
- Active Damping-Based Control for Grid-Connected $LCL$ -Filtered Inverter With Injected Grid Current Feedback Only (2014, neutral): “FOR THE grid-connected inverter in distributed renewable power generations, the LCL-type filter promises a higher rejection of switching harmonics with less weight and volume than the L-type filter [1]–[4].”
- Frequency Adaptive Selective Harmonic Control for Grid-Connected Inverters (2015, positive): “One control goal of the grid-connected inverter is to achieve a unity power factor, and thus, a second-order generalized integrator-based phase-locked loop (PLL) system [1] is adopted to synchronize the grid current with the grid voltage.”
- A New Design Method for the Passive Damped LCL and LLCL Filter-Based Single-Phase Grid-Tied Inverter (2013, background): “1 has been widely adopted [1]–[3] in a large power range.”
- Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions (2011, background): “This is a serious drawback for SRF-PLLs as the voltage waveforms are prone to be distorted and unbalanced as a consequence of the effect of nonlinear loads and assymetrical grid faults [18]–[20].”
- A Review on Grid-Connected Converter Control for Short-Circuit Power Provision Under Grid Unbalanced Faults (2018, background): “Both of [12] and [13] present grid-connected VSC control structures implemented in different reference frames.”
- DC-Bus Voltage Control Stability Affected by AC-Bus Voltage Control in VSCs Connected to Weak AC Grids (2016, neutral): “The conventional VSC control system investigated in this paper consists of two cascaded control loops [22], [23], Fig.”
- Distributed Power System Virtual Inertia Implemented by Grid-Connected Power Converters (2018, neutral): “The reason is that renewable energy sources (RESs), e.g., wind and solar photovoltaics, are normally coupled to the power grid through fast-response power converters, which do not possess any inertia [1].”
- Revisiting Grid-Forming and Grid-Following Inverters: A Duality Theory (2021, background): “3151851 these inverter-based resources (IBRs) have dynamics set by control algorithms of which there are many variants [1], [3], [4].”
- High-power wind energy conversion systems: State-of-the-art and emerging technologies (2015, background): “The harmonic filter in the grid-side converter helps to meet strict harmonic requirements specified by the grid codes [79]–[81].”