Impedance-Based Stability Criterion for Grid-Connected Inverters
By Jian Sun. IEEE transactions on power electronics, 2011
2,282 citations recorded by the source corpus.
Subfields: Control and Systems Engineering, Electrical and Electronic Engineering
View Paper: https://www.semanticscholar.org/paper/58d95335751597d6ff74d1880a1724f61d0a688a
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Control and Systems Engineering
- Frede Blaabjerg
- Xiongfei Wang
- Yun Wei Li
- Yunjie Gu
- T. Green
- Paolo Mattavelli
- Dushan Boroyevich
- Bo Wen
In Electrical and Electronic Engineering
- Frede Blaabjerg
- Xiongfei Wang
- Yun Wei Li
- Yunjie Gu
- T. Green
- Paolo Mattavelli
- Marco Liserre
- Dushan Boroyevich
Citations in the corpus
- Power System Stability With a High Penetration of Inverter-Based Resources (2023, background): “For this reason, the admittance-based method was limited to a specific local problem, that is, a single apparatus (or a cluster of adjacent apparatuses acting in concert) interacting with the rest of the grid, where the point of bipartition is naturally selected as the bus to which the apparatuses u”
- On Resonances and Harmonics in HVDC-MMC Station Connected to AC Grid (2017, methodology): “Frequency domain modeling is also used t assess system stability: modal analysis and the Nyquist stability criterion can be applied ([4] and [8]) on power electronics based systems connected to power systems.”
- Inverse Nyquist Stability Criterion for Grid-Tied Inverters (2017, methodology): “These poles do not appear in the minor loop gain defined in [18] but in the minor loop gain defined by Middlebrook.”
- Online Grid Impedance Measurement Using Discrete-Interval Binary Sequence Injection (2013, background): “In practice, however, this ideal condition never exists and stability of the inverter-grid system requires that the ratio of the grid impedance to the inverter output impedance satisfies the Nyquist criterion [2].”
- Impedance Shaping of the Grid-Connected Inverter with LCL Filter to Improve Its Adaptability to the Weak Grid Condition (2014, methodology): “Suffering from these parameter variations, the current loop gain can be greatly changed, and thereby leading to possible harmonic oscillation or even instability [7].”
- Stability Issues of $Z + Z$ Type Cascade System in Hybrid Energy Storage System (HESS) (2014, methodology): “Similar things have been noticed in the stability analysis of grid-tied inverters application [27].”
- Stability Criterion for Cascaded System With Constant Power Load (2013, methodology): “The popular stability analysis method for cascaded system in dc DPS is based on the impedance criteria [6]–[12], which only”
- Analysis of Resonance Between a VSC-HVDC Converter and the AC Grid (2018, methodology): “in [14]; conclusions show that the resonance between gridconnected inverters and the grid can be studied by applying the Nyquist stability criterion to the ratio of grid impedance”
- Transient Stability Analysis and Control Design of Droop-Controlled Voltage Source Converters Considering Current Limitation (2019, methodology): “Small-disturbance stability of the VSC is evaluated through eigenvalue locus, Nyquist or Routh-Hurwitz stability criterion, which is based on linearizing the system around a specific operating point [20]–[22].”
- Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network (2012, methodology): “IMPEDANCE-BASED NYQUIST STABILITY CRITERION Impedance-based small-signal analysis has been applied in power electronic converter analysis in [12] and [13].”
- Admittance-Based Stability Analysis: Bode Plots, Nyquist Diagrams or Eigenvalue Analysis? (2020, neutral): “, [1], [2].”
- Impedance Modeling of Three-Phase Voltage Source Converters in DQ, Sequence, and Phasor Domains (2017, methodology): “According to the impedance-based stability criterion [2], the HVDC link of the VSC in Fig.”