Modeling of Grid-Connected VSCs for Power System Small-Signal Stability Analysis in DC-Link Voltage Control Timescale
By Hao Yuan, Xiaoming Yuan, Jiabing Hu. IEEE Transactions on Power Systems, 2017
281 citations recorded by the source corpus.
Subfields: Control and Systems Engineering, Electrical and Electronic Engineering
View Paper: https://www.semanticscholar.org/paper/5368255872c525969500a88a02b60f40a0eb9036
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Control and Systems Engineering
In Electrical and Electronic Engineering
Citations in the corpus
- Revisiting Grid-Forming and Grid-Following Inverters: A Duality Theory (2021, methodology): “By contrast, the swing of a PLL grid-following inverter is still ill-defined and underresearched [11], [14].”
- Transient Stability of Voltage-Source Converters With Grid-Forming Control: A Design-Oriented Study (2020, background): “In general, the dynamic of the outer power loop is over ten times slower than that of the inner voltage and current loop [32].”
- Impedance-Based Analysis of DC-Link Voltage Dynamics in Voltage-Source Converters (2019, background): “However, this virtual synchronous generator model limits the VSC dynamics to the timescale of the dc-link voltage control, which is around 100 ms [17].”
- Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters (2018, unknown): “ortional+ Integral (PI) controller is used for the current regulation in the dq-frame to guarantee a zero steady-state tracking error [17]. In general, the timescale of the PLL is around 100 ms [10], [25], which is well decoupled from the timescale of the current control loop (i.e., 1 ms - 10 ms) [1”
- The Small-Signal Stability Analysis of the Droop-Controlled Converter in Electromagnetic Timescale (2019, background): “Numerous small-signal stability issues have been introduced in electromagnetic timescale, such as low-frequency oscillation (LFO) and harmonic oscillation (HO) [3], [5].”
- Understanding Small-Signal Stability of Low-Inertia Systems (2021, background): “Moreover, [23]–[25] highlight some conceptual differences between a traditional and an inverter-based power system in terms of associated control timescales.”
- Modeling Type-4 Wind in Weak Grids (2019, methodology): “Similar analysis has been conducted to demonstrate 10 Hz oscillations due to a VSC with weak grid condition [9], 6 Hz oscillations in Type-4 wind due to grid voltage sag [6], and 9 Hz oscillations in Type-3 wind due to grid voltage sag [8].”