How to detect and reduce movement artifacts in near-infrared imaging using moving standard deviation and spline interpolation
By Felix Scholkmann, S. Spichtig, Thomas Muehlemann, Martin Wolf. Physiological Measurement, 2010
662 citations recorded by the source corpus.
Subfields: Biomedical Engineering, Cardiology and Cardiovascular Medicine, Radiology, Nuclear Medicine and Imaging
View Paper: https://www.semanticscholar.org/paper/2e13c899bfbb3e5109a2bc2747fc5219adc08988
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Biomedical Engineering
- Felix Scholkmann
- Robert J. Cooper
- Louis Gagnon
- Martin Wolf
- Stefan Kleiser
- Andreas Jaakko Metz
- Raphael Zimmermann
- Ursula Wolf
In Cardiology and Cardiovascular Medicine
In Radiology, Nuclear Medicine and Imaging
- Felix Scholkmann
- Robert J. Cooper
- Louis Gagnon
- Martin Wolf
- Stefan Kleiser
- Andreas Jaakko Metz
- Raphael Zimmermann
- Ursula Wolf
Citations in the corpus
- Functional Near-Infrared Spectroscopy and Its Clinical Application in the Field of Neuroscience: Advances and Future Directions (2020, methodology): “Using different methods, similar conclusions were drawn by Shinoura and Yamada (2005).”
- Wavelet-based motion artifact removal for functional near-infrared spectroscopy (2012, methodology): “Scholkmann et al (2010) used a moving standard deviation scheme to detect motion artifacts and applied spline interpolation in the time interval of the motion to model the artifact and subtract it from the signal.”
- Temporal Derivative Distribution Repair (TDDR): A motion correction method for fNIRS (2018, neutral): “Other methods such as the Movement Artifact Reduction Algorithm (MARA) (Scholkmann et al., 2010) and Targeted Principal Components Analysis (tPCA) (Yücel et al.”
- Statistical analysis of fNIRS data: A comprehensive review (2014, neutral): “…compared the performance of the four motion correction methods, including Kalman filtering (Izzetoglu et al., 2010), wavelet-based filtering (Molavi and Dumont, 2012), spline interpolation (Scholkmann et al., 2010), and principal component analysis (Wilcox et al., 2008, 2010; Zhang et al., 2005).”
- A review on continuous wave functional near-infrared spectroscopy and imaging instrumentation and methodology (2014, background): “These are mostly due to changes in light coupling to the tissue, but part could also be due to genuine changes in CBF/CBV, in the fNIRI signal (Izzetoglu et al., 2005; Kurihara et al., 2003; Özgören et al., 2012; Scholkmann et al., 2010; Takahashi et al., 2012; Tax et al., 2011).”
- Motion artifacts in functional near-infrared spectroscopy: A comparison of motion correction techniques applied to real cognitive data (2014, methodology): “, 2012; Molavi and Dumont, 2012), other techniques can perform better for particular fNIRS datasets (Izzetoglu et al., 2010; Scholkmann et al., 2010).”
- A Systematic Comparison of Motion Artifact Correction Techniques for Functional Near-Infrared Spectroscopy (2012, methodology): “In cases where real motion artifact contaminated NIRS data has been used, the utility of a correction technique has been quantified using some measure of improvement in signal-to-noise ratio of the corrected NIRS timecourse (Izzetoglu et al., 2010; Scholkmann et al., 2010; Molavi and Dumont, 2012).”