Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation.
By K. Kuck, J. Brugada, Alexander Fürnkranz, A. Metzner, F. Ouyang, K. J. Chun, Arif Elvan, T. Arentz, Kurt Bestehorn, Stuart J. Pocock and 2 more. New England Journal of Medicine, 2016
1,589 citations recorded by the source corpus.
BACKGROUND Current guidelines recommend pulmonary-vein isolation by means of catheter ablation as treatment for drug-refractory paroxysmal atrial fibrillation. Radiofrequency ablation is the most common method, and cryoballoon ablation is the second most frequently used technology. METHODS We conducted a multicenter, randomized trial to determine whether cryoballoon ablation was noninferior to radiofrequency ablation in symptomatic patients with drug-refractory paroxysmal atrial fibrillation. The primary efficacy end point in a time-to-event analysis was the first documented clinical failure (recurrence of atrial fibrillation, occurrence of atrial flutter or atrial tachycardia, use of antiarrhythmic drugs, or repeat ablation) following a 90-day period after the index ablation. The noninferiority margin was prespecified as a hazard ratio of 1.43. The primary safety end point was a composite of death, cerebrovascular events, or serious treatment-related adverse events. RESULTS A total of 762 patients underwent randomization (378 assigned to cryoballoon ablation and 384 assigned to radiofrequency ablation). The mean duration of follow-up was 1.5 years. The primary efficacy end point occurred in 138 patients in the cryoballoon group and in 143 in the radiofrequency group (1-year Kaplan-Meier event rate estimates, 34.6% and 35.9%, respectively; hazard ratio, 0.96; 95% confidence interval [CI], 0.76 to 1.22; P<0.001 for noninferiority). The primary safety end point occurred in 40 patients in the cryoballoon group and in 51 patients in the radiofrequency group (1-year Kaplan-Meier event rate estimates, 10.2% and 12.8%, respectively; hazard ratio, 0.78; 95% CI, 0.52 to 1.18; P=0.24). CONCLUSIONS In this randomized trial, cryoballoon ablation was noninferior to radiofrequency ablation with respect to efficacy for the treatment of patients with drug-refractory paroxysmal atrial fibrillation, and there was no significant difference between the two methods with regard to overall safety. (Funded by Medtronic; FIRE AND ICE ClinicalTrials.gov number, NCT01490814.).
Subfields: Cardiology and Cardiovascular Medicine, Pulmonary and Respiratory Medicine
View Paper: https://www.semanticscholar.org/paper/e81648bbd96e276f6a68d2dae7ce0127397fe101
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Cardiology and Cardiovascular Medicine
In Pulmonary and Respiratory Medicine
Citations in the corpus
- Explainable AI for Trees: From Local Explanations to Global Understanding (2019, background): “, Minneapolis, MN), which freezes the tissue and has been demonstrated to have a shorter procedure duration compared to radiofrequency ablation [36].”
- 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation (2017, methodology): “Transient ( 6 months) elevation of heart rate, inappropriate sinus tachycardia and reduction of heart rate variability have been observed after PVI.223,257 Others reported an immediate decrease in autonomic function such as deceleration capacity and acceleration capacity after PVI.”