Validation of the GENEA Accelerometer.
By D. Esliger, A. Rowlands, T. Hurst, M. Catt, P. Murray, R. Eston. Medicine & Science in Sports & Exercise, 2011
579 citations recorded by the source corpus.
PURPOSE The study aims were: 1) to assess the technical reliability and validity of the GENEA using a mechanical shaker; 2) to perform a GENEA value calibration to develop thresholds for sedentary and light-, moderate-, and vigorous-intensity physical activity; and 3) to compare the intensity classification of the GENEA with two widely used accelerometers. METHODS A total of 47 GENEA accelerometers were attached to a shaker and vertically accelerated, generating 15 conditions of varying acceleration and/or frequency. Reliability was calculated using SD and intrainstrument and interinstrument coefficients of variation, whereas validity was assessed using Pearson correlation with the shaker acceleration as the criterion. Next, 60 adults wore a GENEA on each wrist and on the waist (alongside an ActiGraph and RT3 accelerometer) while completing 10-12 activity tasks. A portable metabolic gas analyzer provided the criterion measure of physical activity. Analyses involved the use of Pearson correlations to establish criterion and concurrent validity and receiver operating characteristic curves to establish intensity cut points. RESULTS The GENEA demonstrated excellent technical reliability (CVintra = 1.4%, CVinter = 2.1%) and validity (r = 0.98, P < 0.001) using the mechanical shaker. The GENEA demonstrated excellent criterion validity using VO2 as the criterion (left wrist, r = 0.86; right wrist, r = 0.83; waist, r = 0.87), on par with the waist-worn ActiGraph and RT3. The GENEA demonstrated excellent concurrent validity compared with the ActiGraph (r = 0.92) and the RT3 (r = 0.97). The waist-worn GENEA had the greatest classification accuracy (area under the receiver operating characteristic curve (AUC) = 0.95), followed by the left (AUC = 0.93) and then the right wrist (AUC = 0.90). The accuracy of the waist-worn GENEA was virtually identical with that of the ActiGraph (AUC = 0.94) and RT3 (AUC = 0.95). CONCLUSION The GENEA is a reliable and valid measurement tool capable of classifying the intensity of physical activity in adults.
Subfields: Complementary and alternative medicine, Physical Therapy, Sports Therapy and Rehabilitation, Physiology
View Paper: https://www.semanticscholar.org/paper/e5f123be10cced939b11feb961d1d1203334edd1
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Complementary and alternative medicine
In Physiology
Citations in the corpus
- Daily physical activity assessment with accelerometers: new insights and validation studies (2013, background): “Users have the ability to select user-defined sample frequencies ranging from 10 to 80 Hz (27).”
- Age group comparability of raw accelerometer output from wrist- and hip-worn monitors. (2014, methodology): “Previous studies have suggested that a wristworn raw accelerometer accurately assesses overall PA among both children and adults (8,23); however, a wrist-mounted raw accelerometer may present challenges when trying to accurately identify different PA intensity thresholds (28).”