Spatio-temporal point-spread function of fMRI signal in human gray matter at 7 Tesla
By Amir Shmuel, Essa Yacoub, D. Chaimow, Nikos K. Logothetis, Kamil Ugurbil. NeuroImage, 2007
309 citations recorded by the source corpus.
Subfields: Cognitive Neuroscience, Radiology, Nuclear Medicine and Imaging
View Paper: https://www.semanticscholar.org/paper/cf3d4772a787e82477c7a926391ebf12d7313d47
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Cognitive Neuroscience
- Stephen M. Smith
- Olaf Sporns
- Christian F. Beckmann
- Matthew F. Glasser
- Mark William Woolrich
- Steven E. Petersen
- Timothy Edward John Behrens
- Kamil Ugurbil
In Radiology, Nuclear Medicine and Imaging
- Stephen M. Smith
- Matthew F. Glasser
- Kamil Ugurbil
- Christian F. Beckmann
- Olaf Sporns
- Essa Yacoub
- Jesper L. R. Andersson
- Saâd Jbabdi
Citations in the corpus
- The Minimal Preprocessing Pipelines for the Human Connectome Project (2013, background): “Such low frequency correction does not affect the discriminability of neighboring cortical areas with differing myelin contents, whose boundaries exist at a much higher spatial frequency than a sigma of ~14 mm(FWHM = ~33 mm).”
- Pushing spatial and temporal resolution for functional and diffusion MRI in the Human Connectome Project (2013, background): “This confound can be reduced by restricting analysis to gray-matter voxels (e.g., Formisano et al., 2004; Kolster et al., 2010; Shmuel et al., 2007), but it is not eliminated because the BOLD effect extends outside vascular boundaries by about the blood vessel diameter (Ogawa et al., 1993).1 If the…”
- Robust detection of ocular dominance columns in humans using Hahn Spin Echo BOLD functional MRI at 7 Tesla (2007, methodology): “Finally, the point-spread-function (PSF) of the GE BOLD response in gray matter was shown to be approximately time invariant 4 s after stimulation onset (Shmuel et al., 2007), thus, significantly limiting the window of data acquisition where spatial specificity might be gained.”
- Overview of Functional Magnetic Resonance Imaging (2011, background): “Other experiments have reported the use of spin echo rather than gradient echo acquisitions of BOLD contrast, especially at higher fields where T2* is foreshortened.(22) While a modest research effort will continue in improving acquisition technology, the bulk of research in the development of fMRI ”
- The WU-Minn Human Connectome Project: An Overview (2013, background): “Additionally, higher fields increase the relative sensitivity to the microvasculature in BOLD-based functional images (Ogawa et al., 1993; Ugurbil et al., 2003; Uludag et al., 2009), resulting in a smaller point spread function (Shmuel et al., 2007).”
- High-field fMRI unveils orientation columns in humans (2008, methodology): “We recently reported that when avoiding large vessels, the point spread function (PSF) (Gaussian, full-width half-maximum) of GE BOLD signals at 7 T has an upper limit of 2 mm (49), consistent with a GE-BOLD PSF of 1.”
- An integrative model for neuronal activity-induced signal changes for gradient and spin echo functional imaging (2009, methodology): “Nonetheless, one should be aware that the discussion of relative contribution of micro- and macro-vasculature does not address the question of physical point-spread-function (PSF) of MRI (e.g. Shmuel et al., 2007).”
- Laminar analysis of 7 T BOLD using an imposed spatial activation pattern in human V1 (2010, methodology): “Previous studies [e.g., Engel et al., 1997; Menon & Goodyear, 1999; Leite et al., 2004; Shmuel et al., 2007] have reported measures of PSFtang taken by inducing spatial activation patterns in the visual cortex.”
- Resting-state fMRI in the Human Connectome Project (2013, background): “, 2001), significantly reducing the point spread function of the BOLD response; an upper limit of 2 mm FWHM was measured at 7 T (Shmuel et al., 2007).”
- Population receptive field estimates in human visual cortex (2008, background): “In the future, with more precise estimates of the HRF across cortex, it should be possible to extend the HRF analysis to include the spatial component (3–4 mm fullwidth at half-maximum along the cortical surface (Das and Gilbert, 1995; Engel et al., 1997; Iadecola et al., 1997; Malonek and Grinvald,”