Wearable Photoplethysmographic Sensors—Past and Present
By T. Tamura, Yuka Maeda, M. Sekine, Masaki Yoshida. 2014
851 citations recorded by the source corpus.
Photoplethysmography (PPG) technology has been used to develop small, wearable, pulse rate sensors. These devices, consisting of infrared light-emitting diodes (LEDs) and photodetectors, offer a simple, reliable, low-cost means of monitoring the pulse rate noninvasively. Recent advances in optical technology have facilitated the use of high-intensity green LEDs for PPG, increasing the adoption of this measurement technique. In this review, we briefly present the history of PPG and recent developments in wearable pulse rate sensors with green LEDs. The application of wearable pulse rate monitors is discussed.
Subfields: Biomedical Engineering, Cardiology and Cardiovascular Medicine
View Paper: https://www.semanticscholar.org/paper/ca04bcc2fdd9aed2b04e1f17c6bbb62f44dd3668
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Biomedical Engineering
- João Paulo da Silva Cunha
- Sergio Silvestri
- Arturas Kaklauskas
- Zhilin Zhang
- Omer T. Inan
- Ramakrishna Mukkamala
- Emiliano Schena
- Duarte M. Dias
In Cardiology and Cardiovascular Medicine
- Arturas Kaklauskas
- Zhilin Zhang
- Omer T. Inan
- Ramakrishna Mukkamala
- Chang-Sei Kim
- Survi Kyal
- Jin-Oh Hahn
- Lalit K. Mestha
Citations in the corpus
- Wearable Health Devices—Vital Sign Monitoring, Systems and Technologies (2018, background): “One of the problems in blood oxygen saturation measurement is when the patient is anemic [13,38,39].”
- Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum Reconstruction (2015, background): “W ITH the emerging of smart watches and smart wristbands for healthcare and fitness, heart rate (HR) monitoring using photoplethysmography (PPG) [1], [2] recorded from wearers’ wrists becomes a new research topic both in industry and academia.”
- Review on Wearable Technology Sensors Used in Consumer Sport Applications (2019, background): “Initially, there is no current, thus every time the hammer connects to the other side, an open circuit becomes closed.”
- Human Emotion Recognition: Review of Sensors and Methods (2020, background): “(i) the static part of signal depends on the structure of the tissue and the average blood volume arterial and venous blood, and it varies very slowly depending on respiration; (ii) the dynamic part represents changes in the blood volume that occurs between the systolic and diastolic phases of the c”
- Towards Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice (2015, methodology): “The advantage of reflectance-mode PPG is that it is less restrictive in terms of measurement locations [66], [67], [69].”
- Contact-Based Methods for Measuring Respiratory Rate (2019, methodology): “, the green-yellow region of the visible spectrum) at the tissue [233], and (ii) one photodetector, PD, to record the intensity of the non-absorbed light reflected from the tissue [246].”
- Wearable Sensors for Human Activity Monitoring: A Review (2015, background): “based technology [23], [24], sound based [25], based on”