Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview
By Lennart Harnefors, Xiongfei Wang, Alejandro G. Yepes, Frede Blaabjerg. IEEE Journal of Emerging and Selected Topics in Power Electronics, 2016
625 citations recorded by the source corpus.
Subfields: Control and Systems Engineering, Electrical and Electronic Engineering
View Paper: https://www.semanticscholar.org/paper/36207bb569a292c5cf27b4a6486200363f8cd2b4
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Control and Systems Engineering
- Xiongfei Wang
- Frede Blaabjerg
- Yunjie Gu
- T. Green
- Heng Wu
- Poh Chiang Loh
- Mads Graungaard Taul
- Yicheng Liao
In Electrical and Electronic Engineering
- Xiongfei Wang
- Frede Blaabjerg
- Yunjie Gu
- T. Green
- Heng Wu
- Poh Chiang Loh
- Mads Graungaard Taul
- Yicheng Liao
Citations in the corpus
- Analysis of Resonance Between a VSC-HVDC Converter and the AC Grid (2018, background): “5Ts, a positive-real-part of the inner ac impedance is guaranteed [18] and the value considered in [19] and [20] is 1.”
- Unstable Operation of Photovoltaic Inverter From Field Experiences (2018, background): “Inverter control system interactions with external grid characteristics might contribute to the unstable operation [1], [6].”
- Impedance Modeling of Three-Phase Voltage Source Converters in DQ, Sequence, and Phasor Domains (2017, neutral): “2(a) [27], [28].”
- Impedance-Based Analysis of DC-Link Voltage Dynamics in Voltage-Source Converters (2019, background): “In [3], [20], the impedance model of the dc-link voltage control is formulated through the power balance, where only the d-d channel of the input admittance is affected by the dc-link voltage control.”
- Power System Stability With a High Penetration of Inverter-Based Resources (2023, background): “The first decentralized stability criterion is the passivity criterion, which guarantees the small-signal stability of a grid as long as the admittances or impedances of all grid-connected apparatuses are positive-real [85], [86].”
- Passivity-Based Stability Analysis and Damping Injection for Multiparalleled VSCs with LCL Filters (2017, background): “If the grid impedance is also passive, then the whole grid-connected VSC system will be passive and stable [29].”
- The Anatomy of the 2016 South Australia Blackout: A Catastrophic Event in a High Renewable Network (2018, positive): “Moreover, passivity-based design [35], [36] (e.”
- Grid-Synchronization Stability of Converter-Based Resources—An Overview (2020, methodology): “The sideband oscillation is induced by the asymmetrical control dynamics in the dq-reference frame [38], which can be illustrated by Fig.”
- Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters (2018, neutral): “The bandwidth of the PLL is designed much lower than that of the inner current loop [26].”
- On Resonances and Harmonics in HVDC-MMC Station Connected to AC Grid (2017, methodology): “High time delay values tend to give a negative resistance in high frequency (as reported in [11]).”