External Validation of a Widely Implemented Proprietary Sepsis Prediction Model in Hospitalized Patients.
By Andrew Wong, E. Otles, J. Donnelly, A. Krumm, J. McCullough, Olivia DeTroyer-Cooley, J. Pestrue, Marie Phillips, Judy Konye, C. Penoza and 2 more. 2021
764 citations recorded by the source corpus.
Importance The Epic Sepsis Model (ESM), a proprietary sepsis prediction model, is implemented at hundreds of US hospitals. The ESM's ability to identify patients with sepsis has not been adequately evaluated despite widespread use. Objective To externally validate the ESM in the prediction of sepsis and evaluate its potential clinical value compared with usual care. Design, Setting, and Participants This retrospective cohort study was conducted among 27 697 patients aged 18 years or older admitted to Michigan Medicine, the academic health system of the University of Michigan, Ann Arbor, with 38 455 hospitalizations between December 6, 2018, and October 20, 2019. Exposure The ESM score, calculated every 15 minutes. Main Outcomes and Measures Sepsis, as defined by a composite of (1) the Centers for Disease Control and Prevention surveillance criteria and (2) International Statistical Classification of Diseases and Related Health Problems, Tenth Revision diagnostic codes accompanied by 2 systemic inflammatory response syndrome criteria and 1 organ dysfunction criterion within 6 hours of one another. Model discrimination was assessed using the area under the receiver operating characteristic curve at the hospitalization level and with prediction horizons of 4, 8, 12, and 24 hours. Model calibration was evaluated with calibration plots. The potential clinical benefit associated with the ESM was assessed by evaluating the added benefit of the ESM score compared with contemporary clinical practice (based on timely administration of antibiotics). Alert fatigue was evaluated by comparing the clinical value of different alerting strategies. Results We identified 27 697 patients who had 38 455 hospitalizations (21 904 women [57%]; median age, 56 years [interquartile range, 35-69 years]) meeting inclusion criteria, of whom sepsis occurred in 2552 (7%). The ESM had a hospitalization-level area under the receiver operating characteristic curve of 0.63 (95% CI, 0.62-0.64). The ESM identified 183 of 2552 patients with sepsis (7%) who did not receive timely administration of antibiotics, highlighting the low sensitivity of the ESM in comparison with contemporary clinical practice. The ESM also did not identify 1709 patients with sepsis (67%) despite generating alerts for an ESM score of 6 or higher for 6971 of all 38 455 hospitalized patients (18%), thus creating a large burden of alert fatigue. Conclusions and Relevance This external validation cohort study suggests that the ESM has poor discrimination and calibration in predicting the onset of sepsis. The widespread adoption of the ESM despite its poor performance raises fundamental concerns about sepsis management on a national level.
Subfields: Clinical Biochemistry, Epidemiology, Public Health, Environmental and Occupational Health, Evaluation & Benchmarks
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Epidemiology
In Public Health, Environmental and Occupational Health
- Sebastian Gehrmann
- Verena Rieser
- Jekaterina Novikova
- Jessica Zosa Forde
- Margaret Mitchell
- Samuel Albanie
- Inioluwa Deborah Raji
In Evaluation & Benchmarks
- Sebastian Gehrmann
- Verena Rieser
- Yonatan Belinkov
- Jekaterina Novikova
- Ehud Reiter
- Miruna Clinciu
- Ondrej Dusek
- Zdeněk Kasner
Citations in the corpus
- BLOOM: A 176B-Parameter Open-Access Multilingual Language Model (2022, background): “…that are driven by industry actors can lead to inflated expectations about its suitability for use (Brennen, 2018; Brennen et al., 2022), leading to misaligned research and policy priorities (Raji et al., 2022) and potentially dire consequences in e.g. medical applications (Wong et al., 2021).”
- Bias in medical AI: Implications for clinical decision-making (2024, methodology): “A well-known example of sample selection bias is the Epic Sepsis Model (ESM), developed on EHR data to generate automated warnings for clinicians that patients may be developing sepsis [112].”
- The Fallacy of AI Functionality (2022, background): “Deployed AI-enabled clinical support toolsmisallocate prescriptions [182], misread medical images [66, 132], andmisdiagnose [180, 203].”