Non-uniform refinement: adaptive regularization improves single-particle cryo-EM reconstruction
By Ali Punjani, H. Zhang, David J. Fleet. 2019
1,477 citations recorded by the source corpus.
Cryogenic electron microscopy (cryo-EM) is widely used to study biological macromolecules that comprise regions with disorder, flexibility or partial occupancy. For example, membrane proteins are often kept in solution with detergent micelles and lipid nanodiscs that are locally disordered. Such spatial variability negatively impacts computational three-dimensional (3D) reconstruction with existing iterative refinement algorithms that assume rigidity. We introduce non-uniform refinement, an algorithm based on cross-validation optimization, which automatically regularizes 3D density maps during refinement to account for spatial variability. Unlike common shift-invariant regularizers, non-uniform refinement systematically removes noise from disordered regions, while retaining signal useful for aligning particle images, yielding dramatically improved resolution and 3D map quality in many cases. We obtain high-resolution reconstructions for multiple membrane proteins as small as 100 kDa, demonstrating increased effectiveness of cryo-EM for this class of targets critical in structural biology and drug discovery. Non-uniform refinement is implemented in the cryoSPARC software package. Membrane proteins exhibit spatial variation in rigidity and disorder, which poses a challenge for traditional cryo-EM reconstruction algorithms. Non-uniform refinement accounts for this spatial variability, yielding improved 3D reconstruction quality even for small membrane proteins.
Subfields: Ecology, Materials Chemistry, Structural Biology
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Ecology
In Materials Chemistry
In Structural Biology
Citations in the corpus
- Comprehensive phylogenetic analysis of the ribonucleotide reductase family reveals an ancestral clade (2022, neutral): “Duplicate particles were removed using a minimum separation distance of 80 Å, and the remaining particles (108k) were subjected to a non-uniform refinement ( Punjani et al., 2020 ) with C2 symmetry imposed and per-particle defocus and CTF parameter optimization enabled, which yielded a 3.57 Å map.”
- Generation of ordered protein assemblies using rigid three-body fusion (2020, neutral): “…(37 – 41), 3) SAXS sample preparation and analytical tools for data collected at the Structurally Integrated Biology for Life Sciences (SIBYLS) Beamline (42 – 44), 4) negative-stain EM procedures and tools (32, 33, 45, 46), and 5) cryo-EM sample preparation and processing schemes (32, 33, 46 – 57).”
- Multi-particle cryo-EM refinement with M visualizes ribosome-antibiotic complex at 3.5 Å in cells (2021, background): “More advanced regularization schemes have been proposed 37,38 since to deal with this problem.”
- Mapping Neutralizing and Immunodominant Sites on the SARS-CoV-2 Spike Receptor-Binding Domain by Structure-Guided High-Resolution Serology (2020, neutral): “3D refinements were carried out using non-uniform refinement along with per-particle defocus refinement in cryoSPARC (Punjani et al., 2019).”
- 3D Variability Analysis: Resolving continuous flexibility and discrete heterogeneity from single particle cryo-EM (2020, methodology): “For this dataset, refinement resolution of the peripheral transmembrane helices is limited [32], and 3DVA provides insight into the flexibility that causes this limitation.”