This work presents the design, fabrication and testing of a thermally actuated microgripper for the manipulation of single cells and other biological particles. This microgripper has been fabricated with a particular combination of surface micromachining techniques that permit the release of stress-free polymer (SU8)/metal (Au) structures without the use of sacrificial layers. The inclusion of novel thermal actuators, which completely eliminate the parasitic resistance of the cold arm, improves considerably the efficiency of the system and therefore enables large displacements at low input voltages and operating temperatures. Two types of microgripper have been fabricated and tested producing displacements of up to [email protected] at 1.94V input voltage and 78mW power. Micromanipulation experiments have successfully demonstrated the gripping, holding and positioning of a micro-sized object.
Subfields: Atomic and Molecular Physics, and Optics, Biomedical Engineering, Electrical and Electronic Engineering
View Paper: https://www.semanticscholar.org/paper/ad9f2fc6b9625538d6e5846d0606584de99d28e7
Citations in the corpus
- A Review of Automated Microinjection Systems for Single Cells in the Embryogenesis Stage (2016, unknown): “Another form of cell manipulator uses a MEMS microgripper which is usually equipped with a force sensor [98], [103], [146], [147] or with a”