Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort

By Anna Shcherbina, C. Mattsson, Daryl Waggott, Heidi Salisbury, J. Christle, Trevor J. Hastie, Matthew T. Wheeler, Euan A. Ashley. bioRxiv, 2016

604 citations recorded by the source corpus.

Background The ability to measure activity and physiology through wrist-worn devices provides an opportunity for cardiovascular medicine. However, the accuracy of commercial devices is largely unknown. Objective To assess the accuracy of seven commercially available wrist-worn devices in estimating heart rate (HR) and energy expenditure (EE) and to propose a wearable sensor evaluation framework. Methods We evaluated the Apple Watch, Basis Peak, Fitbit Surge, Microsoft Band, Mio Alpha 2, PulseOn, and Samsung Gear S2. Participants wore devices while being simultaneously assessed with continuous telemetry and indirect calorimetry while sitting, walking, running, and cycling. Sixty volunteers (29 male, 31 female, age 38 ± 11 years) of diverse age, height, weight, skin tone, and fitness level were selected. Error in HR and EE was computed for each subject/device/activity combination. Results Devices reported the lowest error for cycling and the highest for walking. Device error was higher for males,greater body mass index, darker skin tone, and walking. Six of the devices achieved a median error for HR below 5% during cycling. No device achieved an error in EE below 20 percent. The Apple Watch achieved the lowest overall error in both HR and EE, while the Samsung Gear S2 reported the highest. Conclusions Most wrist-worn devices adequately measure HR in laboratory-based activities, but poorly estimate EE, suggesting caution in the use of EE measurements as part of health improvement programs. We propose reference standards for the validation of consumer health devices (http://precision.stanford.edu/). Abbreviations (EE) Energy expenditure (HR) Heart rate (GEE) General estimating equation

Subfields: Biomedical Engineering, Cardiology and Cardiovascular Medicine, Complementary and alternative medicine

View Paper: https://www.semanticscholar.org/paper/9f455261c87bef6e2986a1f520716a9b225f7997

How researchers see this paper

The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.

In Biomedical Engineering

  1. Miroslav Muzny
  2. Brinnae Bent
  3. Gunnar Hartvigsen
  4. Ashenafi Zebene Woldaregay
  5. Benjamin A. Goldstein
  6. James K. Min
  7. Warren A. Kibbe
  8. Sameline Grimsgaard

In Cardiology and Cardiovascular Medicine

  1. Miroslav Muzny
  2. Brinnae Bent
  3. Gunnar Hartvigsen
  4. Ashenafi Zebene Woldaregay
  5. J. Halperin
  6. Benjamin A. Goldstein
  7. James K. Min
  8. Warren A. Kibbe

Citations in the corpus