Grader variability and the importance of reference standards for evaluating machine learning models for diabetic retinopathy

By Jonathan Krause, Varun Gulshan, Ehsan Rahimy, Peter Karth, Kasumi Widner, Greg S. Corrado, Lily H. Peng, Dale R. Webster. 2017

503 citations recorded by the source corpus.

PURPOSE Use adjudication to quantify errors in diabetic retinopathy (DR) grading based on individual graders and majority decision, and to train an improved automated algorithm for DR grading. DESIGN Retrospective analysis. PARTICIPANTS Retinal fundus images from DR screening programs. METHODS Images were each graded by the algorithm, U.S. board-certified ophthalmologists, and retinal specialists. The adjudicated consensus of the retinal specialists served as the reference standard. MAIN OUTCOME MEASURES For agreement between different graders as well as between the graders and the algorithm, we measured the (quadratic-weighted) kappa score. To compare the performance of different forms of manual grading and the algorithm for various DR severity cutoffs (e.g., mild or worse DR, moderate or worse DR), we measured area under the curve (AUC), sensitivity, and specificity. RESULTS Of the 193 discrepancies between adjudication by retinal specialists and majority decision of ophthalmologists, the most common were missing microaneurysm (MAs) (36%), artifacts (20%), and misclassified hemorrhages (16%). Relative to the reference standard, the kappa for individual retinal specialists, ophthalmologists, and algorithm ranged from 0.82 to 0.91, 0.80 to 0.84, and 0.84, respectively. For moderate or worse DR, the majority decision of ophthalmologists had a sensitivity of 0.838 and specificity of 0.981. The algorithm had a sensitivity of 0.971, specificity of 0.923, and AUC of 0.986. For mild or worse DR, the algorithm had a sensitivity of 0.970, specificity of 0.917, and AUC of 0.986. By using a small number of adjudicated consensus grades as a tuning dataset and higher-resolution images as input, the algorithm improved in AUC from 0.934 to 0.986 for moderate or worse DR. CONCLUSIONS Adjudication reduces the errors in DR grading. A small set of adjudicated DR grades allows substantial improvements in algorithm performance. The resulting algorithm's performance was on par with that of individual U.S. Board-Certified ophthalmologists and retinal specialists.

Subfields: Ophthalmology, Radiology, Nuclear Medicine and Imaging, Evaluation & Benchmarks, Medical Imaging

How researchers see this paper

The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.

In Ophthalmology

  1. András Hajdu
  2. William T. Freeman
  3. Arunkumar Rajendran
  4. Renzo Perfetti
  5. Elisa Ricci
  6. Palanivel Karthigaikumar

In Radiology, Nuclear Medicine and Imaging

  1. Balázs Harangi
  2. P. Heng
  3. Lequan Yu
  4. Woong Bae
  5. Michal Irani
  6. Ana Maria Mendonça
  7. Chi-Wing Fu
  8. Fabrice Mériaudeau

In Evaluation & Benchmarks

  1. Phillip Isola
  2. William T. Freeman
  3. Greg S. Corrado
  4. Michal Irani
  5. Chi-Wing Fu
  6. Lei Zhu
  7. Gal Elidan
  8. Baocai Yin

In Medical Imaging

  1. P. Heng

Citations in the corpus