Detection of Demagnetization Faults in Surface-Mounted Permanent Magnet Synchronous Motors by Means of the Zero-Sequence Voltage Component
By Julio César Urresty, Jordi-Roger Riba, M. Delgado, Luís Romeral. IEEE transactions on energy conversion, 2012
168 citations recorded by the source corpus.
Subfields: Control and Systems Engineering, Electrical and Electronic Engineering, Electronic, Optical and Magnetic Materials
View Paper: https://www.semanticscholar.org/paper/82978e03bf0de4c27ba91501c1a997c532919285
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Control and Systems Engineering
In Electrical and Electronic Engineering
In Electronic, Optical and Magnetic Materials
Citations in the corpus
- Rare-earth-free propulsion motors for electric vehicles: A technology review (2016, background): “Features required for electric propulsion motors include high efficiency, high torque and power per unit volume, that is, compactness, [12] good dynamic response, simple construction and high reliability (brushless operation).”
- A New Approach to Fault Diagnostics for Permanent Magnet Synchronous Machines Using Electromagnetic Signature Analysis (2013, methodology): “Negative/zero sequence current [16], [17], negative/zero sequence impedance [18], or negative/zero sequence voltage [19], [20] are utilized as indicators for fault detection.”