How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging
By Jesper L. R. Andersson, Stefan Skare, John Ashburner. NeuroImage, 2003
3,303 citations recorded by the source corpus.
Subfields: Radiology, Nuclear Medicine and Imaging
View Paper: https://www.semanticscholar.org/paper/4e5684b1ab78ff5fc1645395c26ce1d46151889f
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Radiology, Nuclear Medicine and Imaging
- Olaf Sporns
- Stephen M. Smith
- Jacques-Donald Tournier
- Matthew F. Glasser
- Saâd Jbabdi
- Alan Connelly
- Jesper L. R. Andersson
- Stamatios N. Sotiropoulos
Citations in the corpus
- The UNC/UMN Baby Connectome Project (BCP): An Overview of the Study Design and Protocol Development (2018, positive): “These distortions are corrected by first applying the TOPUP tool (Andersson et al., 2003) from the FMRIB Software Library (FSL) (Jenkinson et al., 2012), which results in a single corrected image.”
- Multimodal population brain imaging in the UK Biobank prospective epidemiological study (2016, neutral): “While this might not provide statistical certainty for a diagnosis or interventional recommendation, it should allow for single-patient imaging to be used in a similar way to current state-of-the-art patient-tuned genetic testing.”
- The impact of T1 vs EPI spatial normalization templates for fMRI data analyses (2017, methodology): “These are used to distortion correct the EPI data using the FSL topup program [Andersson et al., 2003] and compared with the images that were not distortion corrected.”
- Image processing and Quality Control for the first 10,000 brain imaging datasets from UK Biobank (2017, methodology): “This optimal AP/PA pair is then fed into topup 22 (Andersson et al. (2003)) in order to estimate the b=0 image fieldmap and associated dMRI EPI distortions.”
- The current state-of-the-art of spinal cord imaging: Methods (2013, background): “The two sets of images will exhibit distortions in the opposite direction, allowing distortion corrections to be determined (Andersson et al., 2003; Reinsberg et al., 2005; Voss et al., 2006).”
- Regional specificity of MRI contrast parameter changes in normal ageing revealed by voxel-based quantification (VBQ) (2011, background): “DTI results may also be improved further by explicit correction of susceptibility-related distortions (Andersson et al., 2003; Gallichan et al., 2010).”
- The Minimal Preprocessing Pipelines for the Human Connectome Project (2013, methodology): “This is done using the “topup” tool (Andersson et al., 2003) in FSL5.”
- Towards a comprehensive framework for movement and distortion correction of diffusion MR images: Within volume movement (2017, methodology): “A fi eldmap was calculated for each di ff usion data set using the preceeding b =0 scan with opposing PE direction and the fi rst b =0 volume of the di ff usion data set using the FSL topup tool (Andersson et al., 2003).”
- Capturing the spatiotemporal dynamics of self-generated, task-initiated thoughts with EEG and fMRI (2019, neutral): “Each dataset was co-registered to the standard MNI space as follows: first, for each subject, the fMRI data were B0-unwarped using FSL-TOPUP (Andersson et al., 2003) and brought to the subject's anatomical space using FLIRT with boundary-based registration (Greve and Fischl, 2009) (12 degrees of fre”
- An integrated approach to correction for off-resonance effects and subject movement in diffusion MR imaging (2016, methodology): “However fg and f g0 will also have similar distortions so there will be little difference between the prediction and fg, which means that there is little to drive the registration.”
- Automated quality control for within and between studies diffusion MRI data using a non-parametric framework for movement and distortion correction (2018, methodology): “● Susceptibility-induced distortions : To correct for susceptibility-induced distortions, EDDY uses the off-resonance fi eld estimated by the FSL TOPUP tool (Andersson et al., 2003).”
- In vivo histology of the myelin g-ratio with magnetic resonance imaging (2015, methodology): “For even better registration in future acquisitions, magnetic susceptibility induced distortion could be corrected for using a blip-up blip-down phase encode strategy (Andersson et al., 2003).”
- Metric learning with spectral graph convolutions on brain connectivity networks (2018, methodology): “, 2007) and distortion (Andersson et al., 2003), as well as high-pass filtered to remove temporal drift.”
- Multi-tissue constrained spherical deconvolution for improved analysis of multi-shell diffusion MRI data (2014, positive): “The DW EPI images were preprocessed using the state-ofthe-art pipeline available in FSL, including susceptibility-induced distortion correction using a pair of b = 0 s/mm(2) images acquired with opposite phase encoding directions (Andersson et al., 2003) and combined eddy-current induced distortion ”