The five percent electrode system for high-resolution EEG and ERP measurements.
By Robert Oostenveld, P. Praamstra. Clinical Neurophysiology, 2001
1,927 citations recorded by the source corpus.
Subfields: Cognitive Neuroscience
View Paper: https://www.semanticscholar.org/paper/464e38e5d1aa6fdbe0650f3a9a7697ee2e3387a6
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Cognitive Neuroscience
- C. Michel
- Karl J. Friston
- Micah M. Murray
- Jean Daunizeau
- Stefan J. Kiebel
- Michael A. Nitsche
- Walter Paulus
- Denis Brunet
Citations in the corpus
- Sleep Stage Classification Using EEG Signal Analysis: A Comprehensive Survey and New Investigation (2016, background): “As shown in Figure 3 [84], the black circles indicate positions in the 10/20 system; and gray circles indicate extended positions in the 10/10 placement system measuring the electrical activity of the cerebral cortex [73–76].”
- 10/20, 10/10, and 10/5 systems revisited: Their validity as relative head-surface-based positioning systems (2007, methodology): “To date, a 10/5 system with more than 300 distinct scalp landmarks has been proposed (Oostenveld and Praamstra, 2001), but there is the possibility of excessive landmark setting.”
- Level of participation in robotic-assisted treadmill walking modulates midline sensorimotor EEG rhythms in able-bodied subjects (2012, methodology): “The montage was in accordance with the 5% 10/20 system (EasyCap, Germany) (Oostenveld and Praamstra, 2001).”
- Topographic ERP Analyses: A Step-by-Step Tutorial Review (2008, methodology): “trodes at scalp locations C5 and C6, using standard electrode position nomenclature [46].”
- A technical guide to tDCS, and related non-invasive brain stimulation tools (2015, methodology): “There are several methods for addressing this issue: (1) International 10–20 (or 10–5) electrode placement System (Klem et al., 1999; Oostenveld and Praamstra, 2001), or another gross anatomical coordinate system (Seibt et al., 2015), (2) neuronavigation systems (e.g., MRI guided; Feurra et al., 201”
- The standardized EEG electrode array of the IFCN. (2017, positive): “With the advent of source imaging, high density EEG electrode arrays including 5% electrode positions, were developed, resulting in electrode arrays of up to 345 positions (Oostenveld and Praamstra, 2001).”
- Automated cortical projection of EEG sensors: Anatomical correlation via the international 10-10 system (2009, positive): “The positioning of the sensors on the subject's head was carried out by four different experienced technologists in accordance with the 10–10 system defined in Oostenveld and Praamstra (2001).”
- Principal components analysis of Laplacian waveforms as a generic method for identifying ERP generator patterns: I. Evaluation with auditory oddball tasks. (2006, methodology): “…to explicitly state the simple spherical model used for this particular CSD transformation, and also to provide an easy means for ERP researchers to apply these methods to any EEG montage based on the ten-twenty electrode system (Jasper, 1958) and its extensions (Oostenveld and Praamstra, 2001).”
- Variational Bayesian inversion of the equivalent current dipole model in EEG/MEG (2008, methodology): “This setup is used widely in evoked response potential (ERP) research (Oostenveld and Praamstra, 2001), and represents a challenge to any source localization technique, relative to high-density recordings.”
- Committee report: publication guidelines and recommendations for studies using electroencephalography and magnetoencephalography. (2014, background): “Oostenveld and Praamstra (2001) proposed an extension of the 10-10 system, referred to as the 10-5 system, in order to accommodate electrode arrays with more than 75 electrode sites.”
- Emotion Assessment From Physiological Signals for Adaptation of Game Difficulty (2011, methodology): “In this paper, 19 electrodes were positioned on the skull of the participants according to the 10–20 system [26].”
- Spontaneous brain activity and EEG microstates. A novel EEG/fMRI analysis approach to explore resting-state networks (2010, methodology): “The standard electrode positions on the MNI152 scalp were taken from Jurcak et al. (2007) and Oostenveld and Praamstra (2001).”
- Virtual spatial registration of stand-alone fNIRS data to MNI space (2007, methodology): “First, probe holders for fNIRS are set in a reproducible manner, preferably with the guidance of a stable scalp landmark setting such as the international 10–20 systems or its derivatives, or the 10–10 or 10–5 systems (Jasper, 1958; Chatrian et al., 1985; Nuwer et al., 1998; Klem et al., 1999; Ooste”
- The development of oscillatory and aperiodic resting state activity is linked to a sensitive period in humans (2023, methodology): “The EEG was continuously recorded, referenced to the left ear lobe with 96 Ag/AgCl scalp electrodes (EasyCap GmbH, Herrsching, Germany), mounted in a cap according to the 1010 system (Oostenveld and Praamstra, 2001).”
- Alpha oscillatory activity is causally linked to working memory retention (2023, methodology): “EEG was recorded with Ag/AgCl electrodes at 13 locations according to the international 10 to 20 system [67] (Fp1, Fp2, F7, F3, Fz, F4, F8, C3, Cz, C4, P3, Pz, P4) using an UEA-16BZ amplifier (SYMTOP, Beijing, China).”