Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters
By Bo Wen, Dong Dong, Dushan Boroyevich, Rolando P. Burgos, Paolo Mattavelli, Zhiyu Shen. IEEE transactions on power electronics, 2014
542 citations recorded by the source corpus.
Subfields: Control and Systems Engineering, Electrical and Electronic Engineering, Energy Engineering and Power Technology
View Paper: https://www.semanticscholar.org/paper/36feebb88790d69db7e7fffc0427f1a6ef36e7f9
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Control and Systems Engineering
- Xiongfei Wang
- Frede Blaabjerg
- Marta Molinas
- Paolo Mattavelli
- D. Lu
- Dushan Boroyevich
- Bo Wen
- Rolando P. Burgos
In Electrical and Electronic Engineering
- Frede Blaabjerg
- Xiongfei Wang
- Marta Molinas
- Paolo Mattavelli
- D. Lu
- Dushan Boroyevich
- Bo Wen
- Zhiyu Shen
In Energy Engineering and Power Technology
Citations in the corpus
- An Overview of Assessment Methods for Synchronization Stability of Grid-Connected Converters Under Severe Symmetrical Grid Faults (2019, unknown): “Furthermore, as pointed out in [51], [52], an increasing proportional gain of the PLL will increase the frequency where the phase characteristics cross − 180 ◦ which degrades the stability.”
- Impedance-Based Analysis of DC-Link Voltage Dynamics in Voltage-Source Converters (2019, methodology): “Hence, the impedance matrix is used for the stability analysis [21], [23], which indicates that the negative impedance introduced by the dc-link voltage control is due to the constant power load behavior during the rectifier operation mode of VSCs.”
- Analysis and Performance Enhancement of Vector-Controlled VSC in HVDC Links Connected to Very Weak Grids (2017, background): “PLLs have been investigated for a long time, and many different types have been introduced [11]–[14].”
- The Small-Signal Stability Analysis of the Droop-Controlled Converter in Electromagnetic Timescale (2019, background): “Considering the characteristics of the converters controlled by droop controller with PLL, the PLL would also become a main factor to result in an instable phenomenon in the converterbased ac microgrids [1], [3], [31].”
- Small-Signal Stability Assessment of Power Electronics Based Power Systems: A Discussion of Impedance- and Eigenvalue-Based Methods (2017, background): “Hence, the stability of the system can be determined by checking the GNC on the minor-loop gain [37], G(s)H(s) = Zs(s)Z−1l (s) = [ GHdd(s) GHdq(s) GHqd(s) GHqq(s) ] .”
- A Modified Sequence-Domain Impedance Definition and Its Equivalence to the dq-Domain Impedance Definition for the Stability Analysis of AC Power Electronic Systems (2016, background): “[11], where the coupling related to the first four bullet-points can be identified.”
- AC Stability Analysis and dq Frame Impedance Specifications in Power-Electronics-Based Distributed Power Systems (2017, methodology): “frequency response of Yqq [15]–[19], it is recommended then that impedance specifications be issued for both d- and q-axes in the dq-domain.”