Scintillating double-beta-decay bolometers

By S. Pirrò, J. Beeman, S. Capelli, M. Pavan, E. Previtali, P. Gorla. 2005

152 citations recorded by the source corpus.

We present the results obtained in the development of scintillating double-beta-decay bolometers. Several Mo and Cd based crystals were tested with the bolometric technique. The scintillation light was measured through a second independent bolometer. A 140-g CdWO4 crystal was run in a 417-h live time measurement. Thanks to the scintillation light, the α background is easily discriminated, resulting in zero counts above the 2615-keV γ line of 208Tl. These results, combined with an extreme easy light detector operation, represent the first tangible proof demonstrating the feasibility of this kind of technique.

Subfields: Nuclear and High Energy Physics, Nuclear Energy and Engineering, Radiation

View Paper: https://www.semanticscholar.org/paper/1168bc671e310a63dbcb6f280e47b0cead6dd6a0

How researchers see this paper

The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.

In Nuclear and High Energy Physics

  1. M. Pavan
  2. O. Cremonesi

In Radiation

  1. M. Pavan
  2. O. Cremonesi

Citations in the corpus