Critical heat flux (CHF) for water flow in tubes—II.: Subcooled CHF correlations
By D. D. Hall, I. Mudawar. 2000
209 citations recorded by the source corpus.
Subfields: Mechanical Engineering
View Paper: https://www.semanticscholar.org/paper/0e119855b2f181ea277691d25d38f2367d1f29d5
How researchers see this paper
The researchers whose trusted networks rank it highest, strongest advocate first. Every researcher gets a different order.
In Mechanical Engineering
- J. Lienhard V
- P. Griffith
- G. Kendall
- A. Bergles
- Satish G. Kandlikar
- Suresh V. Garimella
- T. Harirchian
Citations in the corpus
- Boiling and Evaporation in Small Diameter Channels (2003, methodology): “24 heat transfer engineering vol. 24 no. 1 2003 Table 1 Dimensionless azimuthal temperature differences for W = S× D = 2Wb D/W 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 q0 fixed 0.64 0.79 1.0 1.3 1.62 2.1 2.7 3.8 T0 fixed 0.39 0.52 0.66 0.77 0.86 0.93 0.97 0.99 Similar results have been published by Bowers an”
- The 2006 CHF look-up table (2007, methodology): “The skeleton table alues for G > 300 kg m−2 s−1 and X 0 are either maintained or eplaced with the predicted values by Hall and Mudawar (2000) quation, based on a visual observation of the plots produced by licing the look-up table and the data trends (Durmayaz et al., 004).”
- Two-Phase Microchannel Heat Sinks: Theory, Applications, and Limitations (2011, unknown): “Hall and Mudawar correlations [147,148] are based on the Purdue University Boiling and Two-Phase Flow Laboratory CHF database, which contains the largest database for subcooled and saturated CHF in the literature.”